W x L x H 68 x 60 x 54cm
Weight 72kg
Current Type Single-phase 230V
Fuel 15L
Engine displacement 212cc
Start-up type Manual
Engine Type 4-stroke OHV gasoline
Power 4 kVA

Free shipping on orders over 50€ and up to 30kg.
Prices include VAT.
Guaranteed Technical Assistance
Marca de Confiança

What kind of work do you intend to do?

Leave us your contact information, and a specialist will get in touch.


Your message has been sent successfully!
Complete your purchase
Junte os acessórios ao seu produto
399,00€
SAE 10W40 Oil – 4T – 5 Liters
33,50€
Product + Accessories
The price of your product with the selected accessory(ies)
Description
Product Reviews
Forum
Donker's GD3200T 4kVA 230V Gasoline Generator

Donker's GD3200T Gasoline Generator

It is a portable device manufactured to provide electrical power in different contexts, such as domestic use, construction work, outdoor activities or as an emergency power solution.

This model is equipped with a single-cylinder 4-stroke gasoline engine OHV air-cooled, with an approximate displacement of 212 cc and a rated engine power of 7 HP. The ignition is of the CDI type, which contributes to efficient fuel combustion. The generator also integrates automatic voltage regulation (AVR), a technology that helps maintain stable voltage and protect connected equipment against electrical variations.

In terms of performance, this equipment offers a maximum power of 4 kVA. It is suitable for powering power tools, lighting, DIY equipment or small household appliances. It has a very intuitive control panel and is a generator that normally operates with a voltage of 230 V and a frequency of 50/60 Hz, characteristics that make it compatible with most electrical equipment used in domestic and professional environments. The equipment has a manual start! The fuel tank has a capacity of #236fa1;">18 liters, which allows for several hours of continuous operation (always depending on the load used). The engine also has an oil capacity of approximately 0.6 liters, essential to ensure proper lubrication. With a robust design, a sturdy structure, and a carrying handle, this generator is a practical solution for those who need a portable and efficient power source in situations where mains electricity is not available! Accessories included: Electrical plug (Schuko), #236fa1;">Maintenance tools and Single-phase industrial plug

Main Features
  • 4-stroke single-cylinder gasoline engine OHV, air-cooled.

  • Engine power: 7.0 HP / Engine displacement: 212 cc

  • Nominal generator power: 3.5 kVA / Maximum power: 4 kVA

  • Voltage regulation system AVR (Automatic Voltage Regulation).

  • Ignition system CDI.

  • Manual start

  • Engine oil capacity 0.6L.

Donker's GD3200T Gasoline Generator
Technical Specifications

Engine type 4T OHV Single Cylinder Gasoline Engine
Displacement / Power 212 cc / 7HP
Nominal frequency 50/60 HZ
Voltage adjustment AVR (Automatic Voltage Regulation)
Startup Manual
Max power 4 kVA
Fuel tank 15 L
Minimum fuel consumption 313 g/Kwh
Oil tank 0.6 L

Measurements / Dimensions

Length 68 cm
Width 60 cm
Height 54 cm
Weight 72 Kg
Pre-Operational Verification
Please perform the following preparations before operation to ensure proper functioning of the generator; otherwise, it may result in damage to the equipment and reduced durability.

Engine oil level

The engine contains a small amount of oil when you purchase the generator. Before operating the equipment, please fill it with the appropriate amount of oil of the correct type. SAE 10W-30 motor oil is recommended for general use in all temperatures.

NOTE:Perform the check only when the unit is switched off and on a level surface.

Remove the oil filler cap and clean the dipstick

Insert the dipstick into the oil filler hole without screwing it in

If the oil level is below the lower mark on the dipstick, add oil until it reaches the upper mark

Retighten the oil filler cap/dipstick and secure it safely

Pre-Operational Verification

Fuel Level

To ensure proper operation of the generator, it is recommended to fuel the engine with new unleaded gasoline or higher and follow the steps below.

1 - Place the unit on a level surface.

2 -Remove the fuel filler cap.

3 -Check the fuel level and add fuel if necessary. Be sure not to overfill!

WARNING! Fuel expansion in the tank can cause spills and possible fire or explosion. Please do not fill the tank to the brim; leave room for fuel expansion.

4 - Fill the fuel up to the shoulder of the filter/fuel filter.

5 - Replace the fuel filler cap and tighten it securely.

WARNING! Do not add a mixture of gasoline and engine oil intended for 2-stroke gasoline engines, and do not use old fuel. Prevent foreign objects such as dust, water, etc. from entering the tank. Empty the fuel from the tank and carburetor if the unit will not be used for a long period, as fuel degradation during prolonged storage can make it difficult to start the engine.

Safety Instructions

Warning: Danger!

  • Carbon Monoxide - Do not operate the unit in enclosed or partially enclosed spaces, such as rooms, basements, garages, caves, tunnels, etc. Using a generator indoors (or in enclosed or partially enclosed spaces without good ventilation) CAN KILL IN MINUTES. The generator's exhaust gases contain carbon monoxide, a colorless, odorless, and deadly gas.
  • Electric Shock - Do not operate the machine in humid conditions. The generator produces a high voltage; operating in humid conditions can cause electrocution.
  • Fire and Equipment Damage - Do not connect the generator to the building's electrical circuit. Incorrect connections can damage the generator or cause a fire. Fire and/or Explosion - Keep flammable materials at least 1 meter away from the equipment. The generator produces heat during operation. Operating near flammable materials can overheat them, causing a fire. Gasoline and its vapors are highly flammable and explosive under certain conditions and can be easily ignited by cigarette butts, sparks, open flames, hot surfaces, etc. Take care to avoid fuel spills during refueling. Be sure to refuel only after switching off the engine. Burns - Be careful with hot surfaces. The muffler gets very hot during and immediately after engine operation. Accidental contact with hot surfaces, such as the silencer, can cause severe burns. Children - Keep children away from the unit while it is operating.
Questions and Answers
Questions
Product Reviews
Your question has been successfully submitted!
Your response has been successfully sent!

What kind of work do you intend to do?

Leave us your contact information, and a specialist will get in touch.


Your message has been sent successfully!
Bernardinos
CONNECT WITH BERNARDINOS
Ao subscrever, receba e-mails da BERNARDINOS com notícias, ofertas especiais, promoções e outras informações pertinentes.

Leave us your email address and you will be notified as soon as the product is available.

Notification request successfully added!